MW10 Cardiology Patient Simulator "K"ver.2
Deskripsi
Real, comprehensive simulation of patients with heart diseases and arrhythmias - 88 examples. Real touch, with sounds and data recorded from actual patients, provides a true hands-on education. Easy to transport, simulator "K" can be in attendance wherever clinical training is required.
Fitur
Basic Functions
Wide variety of the examples
Simulator "K" contains 88 cases; 12 cases of normal heart sounds, 14 cases of heart disease simulations, 10 cases of arrhythmia simulations and 52 cases of ECG arrhythmia simulations.
Real sounds, real instruments, real anatomy
Sounds are recorded from actual people and reproduced using a high quality sound system. An actual stethoscope can be used. Auscultation sites corresponding to heart valves are located precisely on a life-size manikin body molded from an actual person.
Obtaining reliable auscultation skills
Auscultation is a fundamental approach to cardiac patients, performed widely from general practitioners to cardiologists. Repeated practice is a necessity for learners to differentiate various heart sounds and murmurs. However, opportunities to learn with real patients are limited and could be insufficient. Simulator "K" offers hands-on experience in a diversity of cases.
Cases & Simulation Contents
Normal heart simulation (12 cases) |
Heart disease simulation (14 cases) |
Arrhythmia (10 cases) |
---|---|---|
S2 split (-) HR: 60 S1 split (+) S2 split (+) S2 wide split S3 gallop S4 gallop pulmonic ejection sound S3 and S4 gallop innocent murmur midsystolic click sound S2 split (-) HR: 72 S2 split (-) HR: 84 |
aortic stenosis mitral regurgitation mitral stenosis aortic regurgitation hypertrophic cardiomyopathy mitral steno-regurgitation pulmonic valvular stenosis atrial septal defect ventricular septal defect tricuspid regurgitation acute mitral regurgitation patent ductus arteriosus mitral valvular prolapse dilated cardiomyopathy |
sinus arrhythmia sinus tachycardia sinus bradycardia ventricular premature contraction (1) ventricular premature contraction (2) ventricular premature contraction (3) sino atrial block atrio-ventricular block atrial fibrillation atrial flutter |
Normal jugular venous waves, arterial pulses and cardiac impulses are simulated, as well as heart sounds such as S2 splitting in the pulmonic area and S3 and S4 gallop sounds in the mitral area. | The characteristic findings of the arterial and venous pulse waves are simulated. For example, in ventricular premature contraction, the venous pulsations are normal but arterial pulsation is barely palpable by the premature beat. | Characteristic heart sounds and pulse waves are simulated, Such as, ventricular premature beats. |
ECG: Arrhythmia simulation
- A-01 normal sinus R
- A-02 sinus tachycardia
- A-03 sinus arrhythmia
- A-04 apc solitary
- A-05 apc bigeminy
- A-06 ectopic pacemaker
- A-07 wondering pacemaker
- A-08 coronary sinus R
- A-09 sinus bradycardia
- A-10 ss syndrome
- A-11 atrial fibrillation
- A-12 atrial flutter
- A-13 atrial flutter fib
- B-01 atrial flutter
- B-02 av block
- B-03 av block & crbbb
- B-04 av block (digital)
- B-05 av block (mobitz)
- B-06 av block (mobitz)
- B-07 av block (3:1&4:1)
- B-08 av & crbbb
- B-09 paroxy atr tachy
- B-10 av junc R (svst)
- B-11 av junc R (pat)
- B-12 av junc R
- B-13 av junc contraction
- C-01 V VI pacemaker
- C-02 atrial pacemaker
- C-03 vent pacemaker
- C-04 av seq pacemaker
- C-05 icrbbb
- C-06 crbbb
- C-07 clbbb
- C-08 clbbb
- C-09 clbbb (by ami)
- C-10 wpw syndrome
- C-11 wpw syndrome
- C-12 wpw syndrome
- C-13 vpc (solitary)
- D-01 vpc (quadrigeminy)
- D-02 vpc (trigeminy)
- D-03 vpc (bigeminy)
- D-04 vpc (couplet)
- D-05 pvc (repetitive)
- D-06 pvc (R-on-T type)
- D-07 non-sustained VT
- D-08 vent tachycardia
- D-09 vent flutter
- D-10 vent fibrillation
- D-11 vent R (sinus cond)
- D-12 accel vent rhythm
- D-13 agonal rhythm
In addition to 36 patient simulations on the left page, the software allows in-depth study of ECG in various arrhythmias. The full size graphic ECG is displayed to practice reading the waves using pause and/or calibrator functions. Fifty-two pre-recorded cases are classified into 4 categories, comprised of 13 cases each.